Forum | Documentation | Website | Blog

Skip to content
Snippets Groups Projects
Commit 8239f904 authored by Jakob Hauser's avatar Jakob Hauser Committed by Jonathan Cameron
Browse files

iio: magnetometer: yas530: Correct temperature handling

The raw temperature value is a number of counts from a certain starting
point. The resolution of the temperature counts is different for the YAS
variants.

Temperature compensation for YAS532 version AC seems to be handled differently.
It uses the deviation from 20 degree Celsius [1] whereas YAS530 and older
versions of YAS532 apply solely the t value as a multiplier [2][3].

In funtion yas5xx_read_raw(), add case IIO_CHAN_INFO_PROCESSED. Remove scale
of temperature as this isn't applied.

Additionally correct sign of temperature channel in iio_chan_spec. It's already
defined that way in the yas5xx_get_measure() function.

[1] https://github.com/msm8916-mainline/android_kernel_qcom_msm8916/blob/GT-I9195I/drivers/iio/magnetometer/yas_mag_drv-yas532.c#L442
[2] https://github.com/NovaFusion/android_kernel_samsung_golden/blob/cm-12.1/drivers/sensor/compass/yas_mag_driver-yas530.c#L881-L883
[3] https://github.com/LineageOS/android_kernel_samsung_msm8930-common/blob/lineage-18.1/drivers/sensors/geomagnetic/yas_mag_driver-yas53x.c#L856-L858



Signed-off-by: default avatarJakob Hauser <jahau@rocketmail.com>
Reviewed-by: default avatarLinus Walleij <linus.walleij@linaro.org>
Reviewed-by: default avatarAndy Shevchenko <andy.shevchenko@gmail.com>
Link: https://lore.kernel.org/r/eb45f328c7a81eb622c6a8cfc5c468ea58bbdace.1660337264.git.jahau@rocketmail.com


Signed-off-by: default avatarJonathan Cameron <Jonathan.Cameron@huawei.com>
parent 413cf691
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment