Need higher PWM frequency as default. 25 kHz loses torque. Requesting 50 kHz.
Created by: dmalawey
Yes, optimal frequency depends on the motors. SCUTTLE motors are on the larger side of the spectrum for BB projects. Ours, and most smaller motors will benefit in torque and quietness by increasing this PWM frequency.
Requesting default frequency to be changed to 50 kHz